SEW-Taiwan

SEW New

  • Filter

● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).

● Microprocesser-controlled with advanced safety features.● 4-wire testing only.● Automatic C spike check.● Auto power-off.● Auto data hold.● Large LCD (2000 counts).● Protective terminal cover.     SPECIFICATIONS               Measuring ranges Earth Resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth Voltage 0-200V AC Accuracy Earth Resistance ±2%rdg±3dgt Earth Voltage ±2%rdg±3dgt Earth resistance resolution 0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω Temperature & humidity Operating: 0°C~40°C ≤80% R.H. Storage: -10°C~50°C ≤80% R.H. Dimensions 205(L) x 90(W) x 55(D)mm Weight (battery included) Approx. 380g Power source 1.5V (AA) x 6 Safety standards EN 61010-1 CAT IV 200V EN 61326-1 EN 61557-1 EN 61557-5

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 2500V  5000V Measuring ranges 0-100GΩ 0-200GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries

FEATURES ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.     SPECIFICATIONS       Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ Continuity     Range 0.01Ω~1999Ω Voltmeter     AC V 0-700V DC V 0-950V PI Function ˇ DAR Function ˇ

FEATURES ● The TEL1 is the Basic Test Equipment an Electrician cannot do   without. TEL1 is a Dual Function Test Instrument utilized to Verify   Electrical Wiring Connections and the Functioning of Earth Leakage   / Residual Current Detectors devices by forcing the ELCB/RCD to   trip.     SPECIFICATIONS         Nominal Voltage System 110V-220V-230V-240Vac available - User Selectable at purchase. System Voltage Frequency 50-60Hz Wiring Check Accuracy Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect. Earth / Ground Current Simulator Accuracy Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum. Overall Rating Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST. Resistance Rating Current Injection System uses Resistors which are Not Continuously Rated. Case Material ABS Safety Standard EN 61010-1 EN...

Category: Loop Testers

FEATURES ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles    in the ground or external measuring wires.● Earth measurement uses the real earth current path   and the current generated by the electric network,   without the need for any disconnection.● The Earth Resistance displayed is exactly the earth   resistance that the earth current will need to go   through if an earth fault occurs.   (you do not need to add all the bonding points and    connection paths)● Displays voltage supply at the transformer(Line to   Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll   through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and   earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.    ...

FEATURES Multi-purpose Cable Tester ● 165 CB is an ideal tool which can test the correct pin configuration    for different kinds of cables.● For testing:    -RJ45/RJ11 -USB    -COAX -BNC cable    -Multi-wire cable● Auto-scan and manual-check function● Buzzer sound warning for wire status● 2 LED module indicators on the master unit which can    do both of transmitter and receiver functions for   RJ45/RJ11 cable testing. Users don't need to use the receiving unit.● 165 CB provides a variety for checking cable continuity,  open status, short status and miss-wired.  ● Ground (shielded ) wire test.● LED indication for wire status.● Power source : 9V batteryAmplifier Probe ● The Amplifier Probe is designed to identify and trace  wires or cables within a group without damaging the insulation.   ● The flashlight function for easier cable tracing in the dark.● An LED indication for the signal strength. ● Volume control for increased sensitivity and adjustable   to suit work environment.● Recessed...

FEATURES ● The 890 PR is a Non-Contact phase detector    with flashing LEDs and a beeping buzzer to    show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and     phase sequence detection.● Convenient brightness switch to make the    indication visible in dim areas or sunlight.● Back cover magnet attaches the instrument to   the AC distribution panel offer easy measurement.● 3-Phase AC 75 to 1000V is fitted for detection.● Detect frequency range is from 45 to 65Hz.     SPECIFICATIONS       Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 4.6±0.1V or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 118(L) × 69(W) × 38(D)mm Weight (battery included) Approx. 370g ...