Power Meter

  • Filter
Category: Power Meter

Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems • Voltage, Current, Power Factor and Frequency measurements • Power analysis (Active, Apparent and Reactive power) • Energy analysis (Active, Apparent and Reactive power) • Active power accuracy: ±0.3%rdg±0.2%f.s. • Automatic wiring check function to prevent incorrect connections • Large memory capability (2GB) using built-in SD card interface • Real time & remote measurements using Android application • synchronous measurements between two units of KEW 6305 • Wide selection of clamp sensors allow measurements from 0.1A to 3000A • The instrument automatically recognizes what kind of clamp sensor is connected to it

Category: Power Meter

Simultaneous Power & Power quality measurementsPower/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch)   • Helpful support functionsQuick Start Guide, Wiring check and Sensor detection for easy and reliable measurement   • Measurement with high accuracy Guaranteed accuracy: ±0.3%rdg (energy),±0.2%rdg (voltage/ current) Complies with the International Standard IEC 61000-4-30 Class Sand the European Standard EN50160   • Remote monitoring on PC and Android deviceRemote checking of measurement in real-time is possible via Bluetooth communication.Recorded data can be saved in the supplied SD card.EN50160 report can be generated after survey by PC software.

Category: Power Meter

12 kinds of power measurements Voltage (RMS), Current (RMS), active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor (cos θ), frequency , demand measurement, current flowing on the neutral line(Only on 3 phase 4 wire measurement) Regenerative electric power can be measured Detection of consumption power and regenerative electric power Regenerative electric power: This is the electric power which is generated by private power generator, and is supplied to electric power company. Display 3 different data simultaneously on large screen. 4 types wiring system 1 phase - 2 wire (1ch) (2ch), (3ch) 1 phase - 3 wire 3 phase - 3 wire 3 phase - 4 wire

Category: Power Meter

Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured. • 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis. • One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory. • Direct communication with PC via USB cable

Category: Power Meter

Flicker Sensor Can measure Flicker in combination with KEW6310. For use with following model 6310

Category: Power Meter

Load current clamp sensor Applicable model 5010/5020, 6300, 6305, 6310, 6315

Category: Power Meter

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.

Category: Power Meter

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.